PRODUTCTS  
     
 

 

   
Home > Products > Transmitters & Converters > ISC 2-Channel Isolated Universal Signal Converter / Conditioner / Isolator  
 
  ISC 2-Channel Isolated Universal Signal Converter / Conditioner / Isolator  
 

 

 

Catalog

Manual

RS-485

Software
  • Both channels must be set to same input type
  • The unique Math function
  • PV1,PV2 is the measuring value of Channel 1 and Channel 2 separately. A,B,C is a constant set by user

  • The unique High/Low comparison output The output 1 can scale to PV1 or PV2 whichever is  higher/lower than the other
  • Programmable for various input signals and measuring  range
  • Configurable without Power Connected
  • Full 3-way isolation for 1500 Vrms
  • DIN rail mount
  • Dual channel Input
    Resistance thermometer (Pt100)
    Thermocouple (J,K,T,E,B,R,S,N,C)
    Voltage/Current transmitter (mV/V/mA)
  • Dual 0/4 to 20 mA or 0~10V analogue output (ISC-D) 
  • RS485 communication interface with Modbus RTU 
    protocol (ISC-C)
  • Fault signal on sensor break presettable
 
The Din Rail converter is user configurable using our  software on your PC/notebook . The easy to use software is available free from your supplier or can be downloaded from our web site and should be used in conjunction with the URC-1020 USB cable which incorporates an interface converter necessary for communications.The ISC converter can be configured without any loop or power connected making it easy to configure in the workshop before installation.
 
Specification
Input Thermocouple (T/C) :
industry standard thermocouple types J, K, T, E, B, R, S, N, C (ITS-90).
Pt100 : Excitation 180uA. 2 or 3 wire connection (ITS-90 α =0.00385).
Voltage : -60mVdc to 60mVdc or –10Vdc to 10Vdc.
Current : 0-24mAdc
Accuracy Refer to Table 1 Input Signal
A/D Resolution 16 bits
Input Sampling Rate <200 ms
Power Supply DC 18~36V
Power Consumption 1.7W (max)
Output Current Output : 4~20mA( Resistive load 600Ω max.)
Continuous Voltage Output : 0~10V…( Resistive load 600Ω min.)
Output Resolution 0.6 μ A(15 bits)
Output Response Time <200 ms

Common Mode Rejection Ratio
 (CMRR)

>80 dB
Electromagnetic Compatibility (EMC) En 50081-2, En 50082-2
Galvanic Isolation 2.8 KV. between input and output
Operating Temperature -10 to 50°C
Humidity 0 to 90% RH
Dimension 75mm(W)x87mm(H)x18.5mm(D)
 
Table 1 Input Signal
Input signal Maximum Range Accuracy
Thermocouple J -50 to 1000°C (-58 to 1832°F) ± 1°C
Thermocouple K -50 to 1370°C (-58 to 2498°F) ± 1°C
Thermocouple T -270 to 400°C (-454 to 752°F) ± 1°C
Thermocouple E                 -50 to 700°C (-58 to 1292°F) ± 1°C
Thermocouple B                  0 to 1750°C (32 to 3182°F)                ± 2°C (Note1)
Thermocouple R                 -50 to 1750°C (-58 to 3182°F) ± 2°C
Thermocouple S                 -50 to 1750°C (-58 to 3182°F) ± 2°C
Thermocouple N                 -50 to 1300°C (-58 to 2372°F) ± 2°C
Thermocouple C                 -50 to 1800°C (-58 to 3272°F) ± 2°C
Pt100                 -200 to 600°C (-328 to 1112°F)     ± 0.2°C
mV                 -60mV to 60mV         ± 0.01mV
Voltage (Note2)                 -10 to 10Vdc    ± 1mV
Current (Note2)                  0 to 24mAdc     ± 10μA
 

Note 1: Accuracy is not guaranteed between 0 and 400°C (0 and 752°F) for type B

Note 2: The internal DIP switch should be set

 

The standard unit is supplied set for thermocouple/PT100 inputs.
The transmitters are user configurable. 
Should you require that the factory set the inputs and ranges the full code must be specified

Loop Power Signal Transmitter
Model Type Input Output Isolated
T/C PT100 mV mA V
IST-H Head Mount V V V X X 4-20mA V
IST-D DIN Rail V V V V V 4-20mA V
IST-P Head Mount 0-60KΩ 4-20mA V
NST Head Mount V V V X X 4-20mA X
 
Dual Channel Isolated Signal Converter
Model Type Input Output 1 Output 2 Math Function Independent
Input(*Note)
T/C PT100 mV mA V
ISC-D DIN Rail V V V V V 0-24mA/0-10V 0-24mA/0-10V V X
ISC-C DIN Rail V V V V V 0-24mA/0-10V RS485 V X
ISD-D DIN Rail V V V V V 0-24mA/0-10V 0-24mA/0-10V X V
ISD-C DIN Rail V V V V V 0-24mA/0-10V RS485 X V
ISA-D DIN Rail X X V V V 0-24mA/0-10V 0-24mA/0-10V X V
ISA-C DIN Rail X X V V V 0-24mA/0-10V RS485 X V
*Note: ISD/ISA: Different input type can be set to each channel
ISC: Both channels must be set to same input type

Related Products


Multi-channels Module type PID Controller (MMC)

SD 430 Microprocessor Indicator

VT2000 HVAC / Temperature
Humidity & CO2 Transmitter

MBC Programmable Modbus RS485 Data Link
 
 
 
 
ABOUT l PRODUCTS l SERVICE l NEWS l CONTACT
Copyright © 2015 VERTEX TECHNOLOGY CORP.  TEL . +886-2-2908-7821 E-mail . sales@vertex-tw.com